UV ozone surface cleaning cleans and modifies the surface of materials through the following three effects

  1. Cleaning modification effect due to the energy of light with a wavelength of 184.9 nm
  2. Cleaning modification effect due to the energy of light with a wavelength of 253.7 nm
  3. Cleaning modification effect by generated ozone O3

Normally, the exhaust airflow is adjusted to maximize UV illumination, but it is also possible to check the effects of ozone and other factors.

We measured the change in ozone by adjusting the exhaust air volume in each standard equipment.


Ozone concentration data in chamber ASM1101N

Equipment used

Equipment name Type Manufacturer
UV cleaning and surface modification equipment ASM1101N (S/N 212245) Made by  ASUMI GIKEN, Limited
Ozone decomposition equipment AOZ013(S/N 4) Made by  ASUMI GIKEN, Limited
Ozone Monitor EG-3000D (S/N 1251182) Made by EBARA JITSUGYO CO., LTD.
UV illuminance meter UV-M03A (S/N K303926) Made by ORC MANUFACTURING CO.,LTD.
Anemometer WS-06 (S/N 001/T.018335) Made by CUSTOM corporation
Data Logger GL240 (S/N C10731393) Made by Graphtec Corporation

Measurement conditions

Ozone concentration measurement point: The tip of the intake tube is placed in the center of the duct as much as possible from the duct measurement flange on the rear of the ASM1101N.

UV irradiance (254nm) measurement point: 30mm away from the lamp, center of the stage.


Exhaust airflow 0.45m3/min

Elapsed time [s] 60 120 180 240 300 360 420 480 540 600
Ozone concentration [ppm] 48.7 45.6 44.3 45.7 45.7 46.3 45.7 45.2 46.0 44.2
UV illuminance [mW/cm2] 22.5 21.8 19.8 17.5 16.6 15.2 15.0 15.0 14.8 13.9

排気風量 0.45㎥/min


Exhaust airflow 1m3/min

Elapsed time [s] 60 120 180 240 300 360 420 480 540 600
Ozone concentration [ppm] 18.4 18.6 19.4 18.1 18.5 19.2 19.0 18.6 18.7 19.0
UV illuminance [mW/cm2] 24.2 24.8 23.5 24.3 24.4 24.2 24.4 23.4 24.0 24.0

排気風量 1㎥/min

The UV illuminance itself is lower due to insufficient cooling of the UV lamps because the UV illuminance was suppressed compared to an exhaust air volume of 1 m3 , but the ozone concentration is more than twice as high.


Ozone concentration data in chamber ASM2001N

Equipment used

Equipment name Type Manufacturer
UV cleaning and surface modification equipment ASM2001N(S/N 212734) Made by ASUMI GIKEN, Limited
Ozone decomposition equipment AOZ014(S/N 8) Made by ASUMI GIKEN, Limited
Ozone Monitor EG-3000D (S/N 1251182) Made by EBARA JITSUGYO CO., LTD.
UV illuminance meter UV-M03A (S/N K303926) Made by ORC MANUFACTURING CO.,LTD.
Anemometer WS-06 (S/N 001/T.018335) Made by CUSTOM corporation
Data Logger GL240 (S/N C10731393) Made by Graphtec Corporation

Measurement conditions

Ozone concentration measurement point: The tip of the intake tube is placed in the center of the duct as much as possible from the duct measurement flange on the rear of the ASM1101N.

UV irradiance (254nm) measurement point: 30mm away from the lamp, center of the stage.


Exhaust airflow 0.2m3/min(Fully closed damper)

Elapsed time [s] 60 120 180 240 300 360 420 480 540 600
Ozone concentration [ppm] 90.5 104.1 110.1 122.5 117.1 126.6 130.9 128.0 130.2 128.9
UV illuminance [mW/cm2] 12.2 8.2 6.3 5.1 4.5 4.3 4.7 4.6 4.7 4.7

風速 0.2㎥/min(ダンパー全閉)


Exhaust airflow  1.1m3/min(Damper 1/2 open)

Elapsed time [s] 60 120 180 240 300 360 420 480 540 600
Ozone concentration [ppm] 27.9 27.9 27.3 27.4 26.9 27.3 28.8 28.5 27.7 27.8
UV illuminance [mW/cm2] 33.2 33.0 32.7 32.8 32.3 32.5 32.7 32.7 32.6 32.7

風量 1.1㎥/min(ダンパー1/2開)


Exhaust airflow  11.5m3/min(Damper fully opened)

Elapsed time [s] 60 120 180 240 300 360 420 480 540 600
Ozone concentration [ppm] 23.1 23.1 22.6 22.8 22.6 22.3 23.1 22.3 22.1 23.0
UV illuminance [mW/cm2] 30.7 32.5 32.4 33.1 33.4 33.6 33.4 33.6 33.6 33.7

風量 1.5㎥/min(ダンパー全開)


Ozone concentration data in chamber ASM2503N

Equipment used

Equipment name Type Manufacturer
UV cleaning and surface modification equipment ASM2503N(S/N 212565) Made by ASUMI GIKEN, Limited
Ozone decomposition equipment AOZ093(S/N 201) Made by ASUMI GIKEN, Limited
Ozone Monitor EG-3000D (S/N 1251182) Made by EBARA JITSUGYO CO., LTD.
UV illuminance meter UV-M03A (S/N K303926) Made by ORC MANUFACTURING CO.,LTD.
Anemometer WS-06 (S/N 001/T.018335) Made by CUSTOM corporation
Data Logger GL240 (S/N C10731393) Made by Graphtec Corporation

Measurement conditions

Ozone concentration measurement point: The tip of the intake tube is placed in the center of the duct as much as possible from the duct measurement flange on the rear of the ASM1101N.

UV irradiance (254nm) measurement point: 30mm away from the lamp, center of the stage.


Exhaust airflow 0.5m3/min (Fully closed damper)

Elapsed time [s] 60 120 180 240 300 360 420 480 540 600
Ozone concentration [ppm] 132.3 152.9 151.7 131.3 155.0 137.5 136.9 137.7 137.2 158.9
UV illuminance [mW/cm2] 16.9 17.3 18.0 18.2 17.5 16.4 15.8 15.0 14.2 13.4

風量 0.5㎥/min(ダンパー全閉)


Exhaust airflow 4.3m3/min(Damper 1/2 open)

Elapsed time [s] 60 120 180 240 300 360 420 480 540 600
Ozone concentration [ppm] 32.7 32.9 32.4 32.8 32.5 31.8 32.7 33.0 32.3 32.2
UV illuminance [mW/cm2] 28.0 28.3 28.2 27.9 28.5 28.3 28.4 28.2 28.6 28.9

風量 4.3㎥/min(ダンパー1/2開)


Exhaust airflow 5.5m3/min(Damper fully opened)

Elapsed time [s] 60 120 180 240 300 360 420 480 540 600
Ozone concentration [ppm] 26.8 28.1 27.4 27.5 27.7 27.7 27.9 28.1 27.3 27.2
UV illuminance [mW/cm2] 29.0 29.0 28.9 28.8 29.1 29.0 28.3 28.8 29.1 29.3

風量 5.5㎥/min(ダンパー全開)


※ We also have data for other models. Please feel free to contact us.